Fire Alarm System

Multi-Loop System

UL listed Single Loop Expandable Up To 4 Loop Analogue addressable fire alarm panel with 254 devices of any combination in a loop, 1016 devices of any combination in a panel, Networkable up to 8 panels in a node. Touch key panel with USB inbuilt for Laptop connectivity. Front panel programmable with Loop redundancy.


Features

  • - Indian Manufacturer International standard.
  • - UL Certified (9th Edition)
  • - Touch Keypad for user friendly operation.
  • - Inbuilt USB.
  • - Universal Switched Mode Power Supply.
  • - Modular Construction, Serviceability.
  • - Networkable.
  • - Auto Resettable Fuse.
  • - Surge Protection.
  • - Battery polarity protection.
  • - 32 Bit processor.
  • - Unique protocol feature for fast alarm response.
  • - Inbuilt conventional circuit.
  • - Auto learning facility.
  • - 1016 Devices of any combination per panel.
  • - Multi protocol.
  • - Peer to Peer Networking.
  • - Redundancy : If the main CPU fails, it will raise an alarm like conventional panel.
  • - User friendly circuit.
  • - Device / Detector wise configuration facility.
  • - 2000 Event Storage with Real Time Clock.
  • - Upto 192 grouping facility.
  • - Pre Alarm Action.
  • - All field wiring are power limited and supervised.
  • - Programmable detector sensitivity.
  • - Device type verification.
  • - Earth fault annunciation facility at 0 ohms.
  • - Double Address Sensing.
  • - Loop wise device test .
  • - 40 X 4 Characters LCD display
  • - Maximum 4 numbers of loop card with Class A, Style 5,6 or 7 and Class B Style 4 wiring
  • - Maximum 254 devices (any combination) per loop.
  • - Day / Night Mode facility.
  • - USB 2.0 Interface for PC connectivity (A to B Type).
  • - RS 485 Communication facility for Network / Repeater/ MODBUS / BACnet.
  • - Programmable Auto Silence Facility / AC Loss Delay / Silence Inhibit.
  • - Two no of programmable inputs.
  • - Battery low audio, visual warning.
  • - Three programmable Form C relay for Fire, Fault and Supervisory.
  • - Two no of Supervise Notification Appliance Circuits.


Electrical Specification

Primary Power Programmable Relays Standby Power
120 / 220VAC + 10% -15%, 60 / 50 Hz Type : Form C No of Relays : 3 Relay Contact Rating : 2A @ 30 VDC, 0.5A @ 125VAC. 24V D.C (2 No's of 12V, 40 Ah (Max), Built in for 12Ah) Sealed Lead acid battery
Signaling Line Circuits Charging Circuit Initiating Device Circuits
Loop card : 4 Nos. Maximum. No Devices per loop : 254 Loop resistance : 40? (Max.). Loop capacitance : 0.6 uf (Max.). Loop Current : 300mA (Max.). Charging Voltage 28 V, 0.2V Nominal Charging Current 1.2A (Max.). Class B Style B/C Operation. No of Conventional Zone : 1 Normal Operating Voltage : 14 - 21 VDC. Alarm Current : 15 - 30mA. Short Circuit Current : 45mA Maximum. Loop resistance : 100? Maximum. End-Of-Line Resistor : 4K7, 1/2watt Standby Current : 7mA (2mA for Detectors)
Notification Appliance Circuits D.C. Output Programmable Input Circuit
No of circuits : 2 Class B, Style - Y wiring Operating Nominal Voltage : 24 VDC Nominal Current for NACs : NAC - 1 : 0.9A NAC - 2 : 0.9 A Line Drop : 2.4V End-Of-Line Resistor : 4K7, 1/2 watt D.C. Output Supervised 24VDC, 300mA Max. Normal Operating Voltage : 4-8 VDC. Short Circuit Current : 3mA Maximum. Loop resistance : 100? Maximum. End-Of-Line Resistor : 4K7, 1/2watt Standby Current : 1.25mA